Hydraulic Oil Cooling

Heavy-Duty Hydraulic Oil Cooler with 12V/24V Fan

Keep hydraulic oil at a safe working temperature on the toughest machines. Our heavy-duty hydraulic oil coolers come with a matched 12V or 24V cooling fan, engineered to your excavator or agricultural machinery.

  • Heavy-duty bar-and-plate aluminum core, vacuum brazed
  • Matched 12V / 24V DC cooling fan for mobile machines
  • Custom envelope, mounting and ports to your machine
  • 100% pressure and leak tested before shipment
  • OEM/ODM with your brand and packaging

Facing overheating issues? Send us your specs or drawings — our engineers size the right cooler within 24 hours.

Keep Hydraulic Oil Cool Under Load

A hydraulic oil cooler with a matched 12V or 24V cooling fan removes heat from the oil circuit of excavators, wheel loaders, tractors and other agricultural machinery. Hot oil flows through a finned aluminum core, the fan blows air across the fins, and the cooled oil returns to the tank at a safe working temperature.

We are a heavy-duty hydraulic oil cooler manufacturer - every unit is engineered to your machine's envelope, mounting space and duty, then built and tested in our own factory.

Key Features & Benefits

  • Heavy-duty bar-and-plate core: vacuum-brazed aluminum core delivers maximum cooling in a compact, rugged package.
  • Matched 12V / 24V fan: DC fan selected for the machine's electrical system, with thermostatic control options.
  • Custom fit: mounting brackets, ports and envelope built to your machine - non-standard is our standard.
  • Dust-resistant fins: designed for job-site and field conditions on construction and farm equipment.
  • 100% pressure tested: every cooler tested before shipment, with test reports available.

Product Specifications

ParameterTypical Range
Cooling capacity5 - 200 kW (custom)
Oil flow rate20 - 500 L/min
Maximum working pressureup to 2.5 MPa
Fan voltage12V / 24V DC
Core typeVacuum-brazed aluminum bar-and-plate
ConnectionsG threads, SAE, flanged or custom

How It Works

  1. Hot hydraulic oil enters the cooler from the return line or power unit.
  2. Oil flows through the bar-and-plate core, and heat transfers to the fins.
  3. The 12V or 24V fan blows air across the fins, carrying the heat away.
  4. The cooled oil returns to the tank at a safe working temperature.

Applications & Aftermarket

Heavy-duty hydraulic oil coolers are used on excavators, wheel loaders, bulldozers, tractors, harvesters and other construction and agricultural machinery. We also supply aftermarket replacement coolers compatible with major brands - a fast, cost-effective alternative to OEM parts, built to the original envelope and duty. Use the bar and plate oil cooler sizing guide to confirm the heat load, LMTD and required area before selecting the fan and core.

We also supply cooling for related machines: excavator coolers, bar and plate aluminum oil cooler assemblies and industrial hydraulic oil coolers.

Custom & OEM Manufacturing

Send us your machine model, drawing or duty parameters. We confirm the design and quotation within 24 hours, make a prototype for evaluation, then produce with full testing. See our custom process or contact us.

How to Size a Hydraulic Oil Cooler with a 12V/24V Fan

A hydraulic cooler should be selected from the heat load and the allowable oil temperature, not from the physical size of the old cooler alone. The main inputs are:

  • Hydraulic oil flow rate
  • Heat load generated by pumps, motors and valves
  • Maximum allowable oil temperature
  • Ambient air temperature
  • Required outlet temperature
  • Allowable pressure drop
  • Available installation space
  • Fan voltage and available electrical power

The cooler must remove the heat added by inefficiency in the hydraulic system. If the machine operates continuously at high load, the fan and core must be sized for that sustained condition rather than a short peak. A unit that looks suitable on a warm day may become undersized in high ambient temperature, at altitude or when the oil has become more viscous.

For an existing machine, send the original cooler dimensions, oil flow, working temperature and photos. We can compare the failed or undersized unit with the required duty and propose a replacement envelope.

Choosing 12V or 24V Fan Control

Most mobile machines use a 12V or 24V DC fan because the machine already provides that electrical system. The fan choice must consider:

  • Nominal system voltage
  • Fan current draw and starting current
  • Alternator or battery capacity
  • Fuse and relay rating
  • Airflow at the actual installed pressure drop
  • Dust, mud and vibration exposure
  • Required IP or protection level

A simple on/off fan is suitable for some systems. A thermostat or temperature switch can start the fan only when cooling is needed. Where the load changes frequently, a PWM or variable-speed controller can reduce noise, electrical demand and fan wear while maintaining a more stable oil temperature.

The fan should be matched to the core, not added as an afterthought. More fan power cannot compensate for a core with excessive pressure drop or poor airflow distribution.

Installation and Airflow

Install the cooler where clean air can enter the core and hot air can leave without recirculating. Keep the fan guard, hydraulic hoses and mounting brackets from blocking the effective core area. If the machine operates in dust or crop residue, use a serviceable guard and provide enough clearance for cleaning.

Use flexible hoses or correctly designed piping to prevent engine vibration and chassis movement from loading the cooler connections. Mount the assembly with vibration isolators where required, and avoid over-constraining the core through multiple rigid brackets.

For mobile equipment, confirm:

  • Fan rotation and airflow direction
  • Clearance around the fan blade
  • Protection from reverse airflow during travel
  • Drainage for water and cleaning fluid
  • Access to the core without removing the hydraulic circuit
  • Protection of electrical cables and connectors

Maintenance Checklist

  • Inspect the core and fan guard for dust, mud and crop residue.
  • Clean the fins with low-pressure air or water in the direction recommended for the installation.
  • Check fan blades for damage, imbalance and excess play.
  • Inspect electrical connectors, fuses, relays and control sensors.
  • Confirm that oil flow and pressure drop remain within the design range.
  • Check hoses and flange connections for seepage or movement.
  • Record oil temperature under the same load and ambient condition so trends become visible.

If oil temperature continues to rise after cleaning, the problem may be heat load, oil viscosity, internal leakage or an undersized cooler rather than a dirty core. Review our hydraulic oil temperature guide for troubleshooting context.

Facing overheating issues in your hydraulic system? Send us your specs or drawings - our engineers will size the right cooler for you within 24 hours.

FAQ

Frequently Asked Questions

What is a 12V/24V hydraulic oil cooler with fan?

It is a fan-driven heat exchanger that cools hydraulic oil using a 12V or 24V DC fan, ideal for excavators, wheel loaders and agricultural machinery where the machine's own electrical system powers the fan.

Can you match the cooler to my excavator or tractor model?

Yes. Our hydraulic oil coolers are non-standard products engineered to your machine's mounting space, oil flow and heat load. Send us your model or drawing.

Do you offer aftermarket replacement coolers for major brands?

Yes. We manufacture replacement coolers and radiators compatible with popular excavator and agricultural brands, built to the original envelope and duty.

What is your MOQ and lead time?

MOQ is flexible for evaluation samples. Production lead time is typically 2-4 weeks depending on quantity and design.

Can the 12V/24V fan run continuously?

Yes, if the fan is selected for continuous duty and the electrical system can support its current draw. A thermostat, temperature switch or PWM controller can reduce unnecessary running.

What oil temperature should a hydraulic cooler maintain?

Many hydraulic systems target approximately 40-60 C at normal operating load, but the machine manufacturer's specification always takes priority. The cooler must be sized for the actual duty and ambient conditions.

What information is needed for a replacement cooler?

Send the machine model, oil flow, heat load or temperature rise, working pressure, fan voltage, mounting dimensions, port positions and photos of the original installation.

Need a Custom Oil Cooler Sized for Your System?

Send us your specs or drawings — our engineers will recommend the right cooler within 24 hours.